SHARE THIS ARTICLE
CASE STUDIES
Sand Monitoring: Real-Time Sanding Data to Manage Drawdown and Optimise Well Test Efficiency
Location: North Africa
Industry: Oil and Gas
Real-time sand monitoring enabled an international operator in North Africa to manage drawdown safely and optimise well test efficiency across open-hole completed wells. Following the suspension of an earlier well test due to tubing sand-up, the operator needed immediate visibility of sand production at surface to control choke settings, protect equipment, and identify each well’s maximum sand-free rate.
The Challenge
The previous well test was suspended because limited sanding information led to sand build-up in the tubing. For subsequent well tests, the operator needed to detect sand production at surface in real time and understand how each well responded to the drawdown applied to the formation.
Reliable, immediate sand data was essential for decisions affecting productivity, well test data quality, and operational safety. Basic sediment and water (BSW) measurement would not have provided the required response time and was not suitable for wells producing 100% gas.
SMS Solution
SMS deployed a clamp-on, dual acoustic sand monitoring system upstream and downstream of the dual-pot sand trap within the well test package.
Sanding data from the acoustic sensors was transmitted through SMS SMART software, integrated with the well test company’s data acquisition system. An SMS engineer correlated the sanding data with key flowing parameters, providing real-time qualitative sanding information to support drawdown management, choke control, and safe optimisation of surface equipment.
Value to Client
The clamp-on acoustic sand monitoring system detected solids in the flowing fluid in real time. Matching upstream and downstream acoustic signatures confirmed that solids were flowing through the sand trap, while the absence of a significant differential pressure indicated no meaningful sand deposition. The produced solids were finer than the sand trap mesh size.
SMS interpreted the instantaneous sensor signals and classified sand production as low, moderate, or high, with further classification as transient, stable, or increasing.
This classification supported clear operational decision-making:
-
If sand production remained stable at a moderate level, flowing conditions were held to assess the well’s sanding propensity before making further changes.
-
If sand production increased to an unacceptable level, immediate action was taken to reduce risk and protect people, equipment, and the environment.
Real-time sanding information allowed the operator to determine each well’s sanding tendency relative to drawdown and achieve maximum sand-free production rates. Working collaboratively with the operator and well test company, SMS used the data to optimise surface equipment performance, mitigate erosion and sand deposition risks, and improve the quality and efficiency of well test results.
Real-time sand monitoring enabled an international operator in North Africa to manage drawdown safely and optimise well test efficiency across open-hole completed wells. Following the suspension of an earlier well test due to tubing sand-up, the operator needed immediate visibility of sand production at surface to control choke settings, protect equipment, and identify each well’s maximum sand-free rate.
The Challenge
The previous well test was suspended because limited sanding information led to sand build-up in the tubing. For subsequent well tests, the operator needed to detect sand production at surface in real time and understand how each well responded to the drawdown applied to the formation.
Reliable, immediate sand data was essential for decisions affecting productivity, well test data quality, and operational safety. Basic sediment and water (BSW) measurement would not have provided the required response time and was not suitable for wells producing 100% gas.
SMS Solution
SMS deployed a clamp-on, dual acoustic sand monitoring system upstream and downstream of the dual-pot sand trap within the well test package.
Sanding data from the acoustic sensors was transmitted through SMS SMART software, integrated with the well test company’s data acquisition system. An SMS engineer correlated the sanding data with key flowing parameters, providing real-time qualitative sanding information to support drawdown management, choke control, and safe optimisation of surface equipment.
Value to Client
The clamp-on acoustic sand monitoring system detected solids in the flowing fluid in real time. Matching upstream and downstream acoustic signatures confirmed that solids were flowing through the sand trap, while the absence of a significant differential pressure indicated no meaningful sand deposition. The produced solids were finer than the sand trap mesh size.
SMS interpreted the instantaneous sensor signals and classified sand production as low, moderate, or high, with further classification as transient, stable, or increasing.
This classification supported clear operational decision-making:
-
If sand production remained stable at a moderate level, flowing conditions were held to assess the well’s sanding propensity before making further changes.
-
If sand production increased to an unacceptable level, immediate action was taken to reduce risk and protect people, equipment, and the environment.
Real-time sanding information allowed the operator to determine each well’s sanding tendency relative to drawdown and achieve maximum sand-free production rates. Working collaboratively with the operator and well test company, SMS used the data to optimise surface equipment performance, mitigate erosion and sand deposition risks, and improve the quality and efficiency of well test results.